Installation, Continued, Floor clearances – Desa CCL3018PR User Manual

Page 9: Determining minimum mantel clearances

Advertising
background image

111161-01A

9

9

For more information, visit www.desatech.com

For more information, visit www.desatech.com

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also
meet required clearances between fireplace opening and mantel shelf. If
you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearances

If you meet minimum clearance between mantel shelf and top of
fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearances When
Using a Hood

If minimum clearances in Figure 6 are not met, you must have a
hood. When using a hood there are still certain minimum mantel
clearances required. Follow minimum clearances shown in Figure
7 when using hood.

FLOOR CLEARANCES

A. If installing appliance on the floor level, you must maintain

the minimum distance of 14" to combustibles (see Figure 8).

B. If combustible materials are less than 14" to the fireplace, you

must install appliance at least 5" above the combustible floor-
ing (see Figure 9).

NOTICE: If your installation does not meet the mini-
mum clearances shown, you must do one of the
following:
• operate the logs only with the flue damper open
• raise the mantel to an acceptable height
• remove the mantel.

NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirements of the national product standard.
Follow all minimum clearances shown in this manual.

INSTALLATION

Continued

Figure 6 - Minimum Mantel Clearances Without Using Hood

14"
Min.

Combustible
Material

Noncombustible Material

Hearth

5"
Min.

Combustible
Material

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

Log Set

18", 24", 30"
Models

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood
(GA6050, GA6052)

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

Figure 9 - Minimum Fireplace Clearances Above Combustible
Flooring

Figure 7 - Minimum Mantel Clearances When Using Hood

Figure 8 - Minimum Fireplace Clearances If Installed at Floor
Level

All Models

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

8"

(A)

18"

8"

20"

14"

22"

17"

24"

20"

All minimum
distances are
in inches

Log Set
24"/30" Models

18" Model

2

1

/2

"

6"

8"

10"

INSTALLATION

Mantel Clearances

Floor Clearances