25

100099

TECHNICAL

SERVICE

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

When gas pressure is too low

• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat

When gas quality is bad

• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.

SERVICE

HINTS

SPECIFICATIONS

VGN30B

VN2000BB

BTU (Variable)

15,000/30,000

9,000/18,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

Maximum

10.5"

10.5"

Minimum

4"

4"

Dimensions, Inches (H x W x D)

Heater

23.5 x 25.9 x 8.0

23.5 x 18.5 x 8.0

Carton

25.8 x 28.7 x 10.1

25.8 x 21.3 x 10.1

Weight (pounds)

Heater

30

22

Shipping

35

27