OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem-

perature drops to a lower than ideal comfort level

before the log set comes back on, you may want

to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the

gas valve assembly on the mounting bracket.

This location allows the thermostat to keep the

room temperature at an ideal comfort level for

most fireplace applications. For positioning the

thermostat sensing bulb elsewhere, an adhesive-

backed mounting clip is available.

Tools needed: 1/4" hex driver or socket

1. Remove logs. Locate the gas valve assembly

and thermostat sensing bulb (see Figure 38).

2. With 1/4" hex driver or socket, loosen the ther-

mostat screw. Carefully slide the thermostat

sensing bulb out of the retaining clamp (see

Figure 40).

Note: Do not remove the screw. Make sure

you tighten the screw after removing the

thermostat sensing bulb.

IMPORTANT: Do not force or bend the

thermostat sensing bulb or capillary.

3. The thermostat sensing bulb may be located to

the lower right front side of fireplace. Determine

location of sensing bulb, but do not mount sens-

ing bulb until step 4. If you have a masonry fire-

place, see Figure 41 for location. If you have

a factory-built metal fireplace, see Figure 42

for location. If your fireplace has glass doors,

position sensing bulb directly behind door gap

on right bottom side (see Figure 43).

Thermostat
Sensing
Bulb

Gas Valve
Assembly

Mounting
Bracket

Figure 38 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 39 - Adhesive-backed Mounting Clip

Figure 40 - Removing Thermostat

Sensing Bulb

Thermostat
Screw

Retaining
Clamp

Thermostat
Sensing
Bulb

Capillary

Adhesive-backed
Mounting Clip

Thermostat
Sensing Bulb

Figure 41- Locating Thermostat Sensing

Bulb on Masonry Fireplace

Figure 42 - Locating Thermostat Sensing

Bulb on Factory-built Metal Fireplace

Adhesive-
backed
Mounting Clip

Thermostat
Sensing Bulb

Adhesive-backed
Mounting Clip

Thermostat
Sensing Bulb

Glass Doors

Figure 43 - Installing Thermostat Sensing

Bulb Behind Glass Doors