STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT

Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.

• A maximum of 1-hour is allowed to diagnose a defective component.

• A maximum of 1-hour is allowed for retrieval of parts not in stock.

• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.

• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or

correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work

Authorization from Delfield. You must submit the number with the service claim.

LABOR OF 1-HOUR IS ALLOWED TO REPLACE:

• Thermostat

• Contactor/Relay

• Infinite Switch

• Transformer

• Door Jamb Switch

• Evaporator/Condenser Fan Motor and Blade

• Solenoid Coil

• Circulating Fan Motor and Blade

• Hi-limit/Thermal Protector Switch

• Microprocessor Control

• Fan Delay/Defrost Termination Switch

• Water Level Sensor/Probe

• Compressor Start Components and Overload Protector

• Door Hinges, Locks, and Gaskets

• Defrost Timer

• Condensate Element

• Thermometer

• Springs/Lowerator

• Gear Box

LABOR OF 2 HOURS TO REPLACE:
• Drawer Tracks/Cartridges

• Defrost Element

• Pressure Control

• Heating Element

• Solenoid Valve

• Locate/Repair Leak

LABOR OF 3 HOURS TO REPLACE:
• EPR or CPR Valve

• Condenser or Evaporator Coil

• Expansion Valve

LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$35.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,

solder, brazing rod, nitrogen, or similar fees.)

REFRIGERANTS
• R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
• R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
• R404A A maximum of $12.00/lb. or 75¢/oz. will be reimbursed.