ABUS Technologies SMART PRESSURE TRANSMITTER (501P) User Manual

Description, Technical specifications, Physical specifications

Advertising
background image

DESCRIPTION

MIEPL

501P Smart Pressure Transmitter uses as its measuring principle, the well

known and field proven technique of sensing a crystal silicon chip and a
diaphragm micro-machined into the chip, enhanced by microprocessor based
electronics.

Designed for process control applications, these 2-wire transmitters generate a
4-20 mA signal proportional or characterized to the applied pressure. This signal can be transmitted over a pair of twisted wires
through long distances (limited only by the wire resistance and load). Remarkable features of the transmitters are its 0.075%
inaccuracy and non-linearity(optional), 20:1 rangeability, compactness and light weight.

The pressures are directly applied to the isolating diaphragm that provide isolation and resistance against process fluid corrosion.
Being microprocesor based, the electronic circuit is extremely versatile and accurate. Combined with the sensor precision, it
provides the high accuracy and rangeability.

Transmitter performance is improved by continuous monitoring of the sensor temperature and corresponding auto corrections.

A local display permits easy reading and writing of data and easy configuration of device parameter without requiring Hart
Communicator.

TECHNICAL SPECIFICATIONS

Functional Specifications

Performance Specifications

Process Fluid

: Liquid, gas or vapor

Range

: 0-0,0016 to -1-0-600 bar

Output signal

: Two wire 4-20, 20-4 mA and HART

protocol

Power supply

: 12 -45 VDC

Load limitation : 0-600Ω for 24VDC
Indicator

: LCD Indicator

Hazardous area* : IP67 weather-proof, intrinsically safe and

explosion proof EEx ia, EExd IIC, T6, T5, to
EN 50.014, EN 50.018 and EN 50.020 for
Zon 0 IIA, IIB, IIC

Zero and span

: Non-interactive local adjustment

Ambient Temp. : -20 to 80°C display -10 to 70°C
Process Temp.

: -20 to 80/130°C, -65 to 150°C, 0 to 200, 0-

350°C

Storage Temp. : -40 to 85°C
Turn-on time

: Performs within specifications in less than

120 milliseconds after power is applied

Overpressure

: 400%

Humidity limits : 0 – 100% RH
Damping Adj.

: Adjustable

Configuration

: By push button on the transmitter or HC,

PC using HART

Protocol

Resolution

: ±0.01 %

Inaccuracy

: ±0.1%

Temperature effect : ±0.1 %/10K Zero and Span
Power Supply effect : Negligible between 12 and 45 VDC
Mounting Effect : Any position, No span effect
EMC

: EN 50081-1, EN 50082-2, 89/336/EEC


Physical Specifications

Electrical Connection : ½” – 14 NPT
Process Connection : M G1/2, M20, G½NPT, cassette type
Wetted parts

: AISI 316L or Hastelloy

Filling fluid

: Silicone oil

Electronic housing : Injected aluminum with polyester

painting (RAL 5014) NEMA 4X, IP66

Identification plate : 304 SS*
Approximate weight : 1.6 kg
Mounting : Directly supported by piping or

optionally with mounting bracket for
2” pipes or with direct or remote
seats

*Optional

•

HART Protocol communication interface

•

0.1% inaccuracy and non-linearity

•

High Rangeability

•

0 – 0.0016 bar (1. 6kpA) till -1/0 -600 bar

•

Automatic temperature compensation

•

4 - 20 mA output

•

True non-interactive zero and span

•

Local zero and span adjustment

•

Totally Field configurable with keypad

•

Bright Backlit LCD indicator

•

Adjustable damping

•

Indication in engineering units

•

AISI 316L or Hasteloy C Wetted P

•

Robust design

•

Small and light weight

•

Weather-proof housing

•

Intrinsically safe as option

•

Explosion Proof as option