OPTIONAL POSITIONING

OF THERMOSTAT

SENSING bULb

FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem-

perature drops to a lower than ideal comfort level

before the log set comes back on, you may want

to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located on the left

side of the base assembly. This location allows the

thermostat to keep the room temperature at an ideal

comfort level for most fireplace applications. For

positioning the thermostat sensing bulb elsewhere,

an adhesive-backed mounting clip is available.

1. Locate the gas valve assembly and thermostat

sensing bulb (see Figure 31).

2. Gently pull thermostat sensing bulb free from

the retaining clamp.

IMPORTANT: Do not force or bend the

thermostat sensing bulb or capillary.

3. The thermostat sensing bulb may be located

to the lower right front side of fireplace. De-

termine location of sensing bulb, but do not

mount sensing bulb until step 4. If you have a

masonry fireplace, see Figure 33 for location.

If you have a factory-built metal fireplace, see

Figure 34 for location.

If your fireplace has glass doors, position

sensing bulb directly behind door gap on right

bottom side (see Figure 35).

4. The mounting clip must be a minimum of 3"

from bottom of fireplace to prevent crimping

of capillary. Once you have decided on a

location, clean the area thoroughly. Remove

the paper backing from the adhesive on back

of mounting clip. Press the clip into the new

location so that the thermostat sensing bulb

will be positioned vertically with the capil-

lary at the bottom (see Figure 36). Slide the

thermostat sensing bulb into the clip.

IMPORTANT: Do not crimp capillary.

Figure 31 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Figure 32 - Adhesive-backed Mounting Clip

Figure 33 - Locating Thermostat Sensing

Bulb on Masonry Fireplace

Figure 34 - Locating Thermostat Sensing

Bulb on Factory-built Metal Fireplace

Adhesive-backed
Mounting Clip

Thermostat
Sensing Bulb

Figure 35 - Installing Thermostat Sensing

Bulb Behind Glass Doors

Figure 36 - Positioning the Thermostat

Sensing Bulb in the Vertical Position

with the Capillary at the Bottom

Adhesive-
backed
Mounting
Clip

Glass Door

Thermostat
Sensing
Bulb

Capillary

Thermostat
Sensing Bulb

Do Not Crimp
Capillary

Adhesive-backed
Mounting Clip

Adhesive-
backed
Mounting Clip

Thermostat
Sensing Bulb

Gas Valve
Assembly

Thermostat
Sensing Bulb

Retaining
Clamp