CLEARANCES TO COMBUSTIBLE MATERIALS

It is of utmost importance that the clearances to combustible material mentioned on your wood stove
certification plate be scrupulously respected upon installation.

CLEARANCES

Model

Back Wall

Side Walls

Corners

* Height

Baron 1880sp

18" / 610 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Baron 2000sp

24" / 610 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Baron 1880sp
with envelope

15" / 381 mm

26,5’’ / 673mm

26,5’’ / 673mm

7' / 2,13 m

Baron 2000sp
with enveloppe

15" / 381 mm

26,5’’ / 673mm

26,5’’ / 673mm

7' / 2,13 m

Cassandra

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Compak

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Contempro 1300

14" / 355 mm

26" / 660 mm

15" / 381 mm

7' / 2,13 m

Contempro 1600

12" / 305 mm

24" / 610 mm

15" / 381 mm

7' / 2,13 m

Contempro 2000

12" / 305 mm

24" / 610 mm

15" / 381 mm

7' / 2,13 m

CS 1200

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Gemini 1200

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Gemini 1500

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Jasper

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Klondike

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Little Sawman

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Lorraine

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

ML

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Patriarch

48" / 1219 mm

36" / 914 mm

24" / 610 mm

7' / 2,13 m

RC

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Nordic

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Sawman

16" / 406 mm

30" / 762 mm

30" / 762 mm

7' / 2,13 m

Sawyer

36" / 914 mm

38" / 965 mm

24" / 610 mm

7' / 2,13 m

Settler

32" / 813 mm

32" / 813 mm

22" / 559 mm

7' / 2,13 m

Whistler, DLX

16" / 406 mm

16" / 406 mm

16" / 406 mm

7' / 2,13 m

Single Pipe / Double

Single Pipe / Double

Single Pipe / Double

Classic

16" (406mm) / 12" (305mm)

22" (559mm) / 22" (559mm)

11" (279mm) / 11" (279mm)

7' / 2,13 m

Fx 3000

14 1/2"(368mm) / 4 /2"(114mm)

12" (305mm) / 12" (305mm)

4" (102mm) / 4" (102mm)

7' / 2,13 m

Royal Comfort

17" (432mm) / 8" (203mm)

13" (330mm) / 13" (330mm)

16”(406mm) / 10”(254mm)

7' / 2,13 m


* Height, from stove base to ceiling.

You may decrease these clearances by installing heat radiation shields between the walls or the ceiling and
the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid
non-combustible sheet or a masonry wall. The installation standards of such heat radiation shields are listed
on the following page.

IT IS STRICTLY FORBIDDEN TO PLACE WOOD WITHIN THE MINIMUM CLEARANCES.

Advertising