3 powerline utility – AXING SPL 2-00 User Manual

Page 13

Advertising
background image

Operation Instructions SPL 2-00/-01

Chapter 4: Troubleshooting

26.11.12

© AXING AG • Reserving change in design and type - We cannot be held liable for printing errors

13

Powerline LED
• Off. The Powerline devices cannot find each other. Make sure that the Powerline

devices are plugged into outlets with power, and that they use the same network

security key.
– Move the Powerline device to a location closer to the computer or devices.
– If you have set up network security, make sure that all Powerline devices are

using the same security key.

– If the problem occurred after you changed the network security key, reset each

device to its factory default settings. Then you can customize the security key.

• Red. Move the Powerline device to a closer location.

4.3 Powerline Utility

Î

Download for free http://www.axing.com

Basic Functioning
If you click Connect on the main screen of the Powerline Utility, and do not see all the

devices you expect, it could be that a Powerline adapter is in power sleep mode or is
set to use a different security key.
• Power sleep mode. If a unit goes into power sleep mode, the Powerline Utility

does not find it. Keeping a connected Ethernet cable plugged into the device keeps
it active so that it does not go in to power sleep mode.

• Security keys are different. To fix this, you can do one of the following:

– Reset your Powerline adapters to their factory settings and default security key.

Then set the security for all of your Powerline adapters.

– Connect your computer to each


Advertising