Casella CEL Software for Nomad (Standard Operation) User Manual

Page 24

Advertising
background image

For example:

2

Value

Text

89

First quadrant (0 - 89)

179

Second quadrant (90 - 179)

269

Third quadrant (180 - 269)

359

Fourth quadrant (270 - 00)

When these settings receive data from a wind direction channel, the multi-

text display would indicate from which quadrant the wind is currently blowing.

3.4

Saving the Display File

When all items required for the display page or pages have been added and

positioned, you can save the screen layout for re-use.
1.

Select the

File

menu and use the

Save As...

option.

2.

Enter a suitable filename and file path in the Save As dialog.

3.

Press

Save

to save your choice.

The screen layout, including all pages, will be saved, and can be

loaded for use at any time via the

File

menu and the

Open...

option.

If required, a screen layout can be loaded automatically and switched to run in

real-time mode when you start the Online Pro software as described in

Section 2.5.

The

Save Screen Image...

option on the File menu allows the,

current screen to be saved as a bitmap. In addition to general record keeping,

this feature is particularly useful for recording special events.

3.5

Lock Layout

This option allows you to protect the current screen layouts from both

inadvertent and intentional (but unauthorised) change.

The display will continue to update in real-time and scroll between

pages when required, however, none of the display positions or properties

can be modified.

3.6

Web Page Output

This option allows real-time information to be written to an HTML file for

viewing via an intranet or the internet.

The output is configured via the

Web Page Output

dialog obtained

by using the

Web page output...

option on the

View

menu.

Online Pro outputs data in real-time to an intranet/internet page by

replacing text in a template file with the measured data. This allows you to

have full control over the format of the page.

To enable web output, select the check box, use the first Browse

button to select the template HTML file, then use the second Browse button

to specify the name/location of the output file. (Usually this will be on a

server.)

Real Time

Note 2: The “Value” of the last entry in the list is not used, as the message for the

preceding list entry will be displayed for all values above its trigger value.

ONLINE Pro Application Software for

Automatic Monitor Systems - Users Handbook

Page 24 of 68

Advertising