Strap-toggle, Specification & design manual, Ordering information – Crimson HT User Manual
Page 2

Tension
Shear
Tension
Shear
lbs.
lbs.
lbs.
lbs.
(kN)
(kN)
(kN)
(kN)
3/16
30
60
35
70
50
95
50
110
(4.8)
(0.1)
(0.3)
(0.2)
(0.3)
(0.2)
(0.4)
(0.2)
(0.5)
1/4
35
70
35
75
55
105
55
120
(6.4)
(0.2)
(0.3)
(0.2)
(0.3)
(0.2)
(0.5)
(0.2)
(0.5)
3/8
35
70
40
75
55
105
60
120
(9.5)
(0.2)
(0.3)
(0.2)
(0.3)
(0.2)
(0.5)
(0.3)
(0.5)
1/2
35
75
40
90
55
110
60
120
(12.7)
(0.2)
(0.3)
(0.2)
(0.4)
(0.2)
(0.5)
(0.3)
(0.5)
3/16
120
240
130
285
195
380
205
440
(4.8)
(0.5)
(1.1)
(0.6)
(1.3)
(0.9)
(1.7)
(0.9)
(2.0)
1/4
130
270
145
295
210
420
215
470
(6.4)
(0.6)
(1.2)
(0.7)
(1.3)
(0.9)
(1.9)
(1.0)
(2.1)
3/8
135
275
150
300
220
420
230
475
(9.5)
(0.6)
(1.2)
(0.7)
(1.4)
(1.0)
(1.9)
(1.0)
(2.1)
1/2
140
290
150
355
220
430
230
485
(12.7)
(0.6)
(1.3)
(0.7)
(1.6)
(1.0)
(1.9)
(1.0)
(2.2)
Anchor
Diameter
d
in.
(mm)
SPECIFICATION & DESIGN MANUAL
Strap-Toggle
TM
1. The values listed above are ultimate load capacities which should be reduced by a minimum safety factor of 4.0 or greater to determine the allowable working load.
Tension
Shear
Tension
Shear
Tension
Shear
Tension
Shear
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
3/8" Wallboard
1/2" Wallboard
5/8" Wallboard
3/4" Wallboard
Anchor
Diameter
d
in.
(mm)
Tension
Shear
Tension
Shear
Tension
Shear
Tension
Shear
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
lbs.
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
(kN)
3/8" Wallboard
1/2" Wallboard
5/8" Wallboard
3/4" Wallboard
PERFORMANCE DATA
Ultimate Load Capacities for Strap-Toggle in Wallboard
1
1. Allowable load capacities listed are calculated using an applied safety factor of 4.0.
Allowable Load Capacities for Strap-Toggle in Wallboard
1
Anchor
Diameter
d
in.
(mm)
Ultimate and Allowable Load Capacities for Strap-Toggle in Hollow Concrete Masonry
1,2
3/16
1/2
0
5
1
5
1
2
0
4
7
0
8
0
,
1
(4.8)
(12.7)
)
7
.
0
(
)
0
.
1
(
)
3
.
3
(
)
9
.
4
(
1/4
1/2
5
8
2
0
7
2
0
2
4
,
1
5
5
3
,
1
(6.4)
(12.7)
)
3
.
1
(
)
2
.
1
(
)
4
.
6
(
)
1
.
6
(
3/8
3/4
5
6
4
5
8
2
0
3
3
,
2
5
3
4
,
1
(9.5)
(19.1)
)
1
.
2
(
)
3
.
1
(
)
5
.
0
1
(
)
5
.
6
(
1/2
3/4
5
9
5
5
4
3
0
8
9
,
2
0
2
7
,
1
(12.7)
(19.1)
)
7
.
2
(
)
6
.
1
(
)
4
.
3
1
(
)
7
.
7
(
f´
m ≥
1,500 psi (10.4 MPa)
Drill
Bit
Diameter
d
bit
in.
(mm)
d
a
o
L
e
l
b
a
w
o
ll
A
d
a
o
L
e
t
a
m
i
t
l
U
1. Tabulated load values are for anchors installed in minimum 6-inch wide, Grade N, Type II, medium and normal-weight concrete masonry units. Mortar must be minimum Type N.
2. Allowable loads are based on average ultimate values using a safety factor of 5.0.
Cat. No.
Anchor Size
Drill Diameter
Wall Thickness
Std. Box Std.Carton Wt./100
4052
3/16" x 4"
1/2"
3/8"- 2 1/2"
50
300
3 1/2
4054
1/4" x 4"
1/2"
3/8"- 2 1/2"
50
300
3 1/2
4056
3/8" x 4"
3/4"
3/8"- 2 1/2"
25
150
5
4058
1/2" x 4"
3/4"
3/8"- 2 1/2"
25
150
5
Strap-Toggle
(Not packaged with screws)
ORDERING INFORMATION