Wand emulation, Wand emulation -26, Supported symbologies -26 – Datalogic Scanning 1000I User Manual

Page 52: Wand emulation barcode format -26

Advertising
background image

Interface Related Features

3-26

Magellan

®

1000i

Wand Emulation

Supported Symbologies

The Wand Emulation interface will transmit barcode data as a wand device would. This inter-
face will transmit the following barcode symbologies:

•

UPC/EAN

•

UPC/EAN with addons

•

Code 39

•

Full ASCII Code 39

•

Interleaved 2 of 5

•

Codabar

•

Code 128

Pharmacode 39 is transmitted as Code 39. All other barcode symbology types read by the scan-
ner will be transmitted as Code 128.

Wand Emulation Barcode Format

The following format settings are required for the wand emulation interface. These settings have
been pre-configured at the factory for Wand Emulation scanners.

•

UPC-A barcodes must include all 12 digits.

•

UPC-E barcodes must contain 8 digits, including a system digit, 6 data digits, and the
check digit.

•

EAN-13 barcodes must have all 13 digits.

•

EAN-8 barcodes must include all 8 digits.

•

Code 39, Code 39 Full ASCII, and Pharmacode 39 barcodes must NOT contain start /
stop characters.

•

Codabar barcodes must include the start / stop characters, presented in the ABCD format.

•

Interleaved 2 of 5 barcodes must have an even number of digits.