SYMPTOM

Burner fails to light

Burner lights but goes out
when automatic control valve
button is released

Maximum burn rate is low

TROUbLESHOOTING

WARNING: Never attempt to service heater while it is connected

to propane/LP supply, operating, or hot. Severe burns can occur.

POSSIBLE CAUSE

1. Propane/LP supply valve

closed on propane/LP cyl-
inder

2. Blockage in burner/orifice

elbow/hose and regulator
assembly

3. Battery not installed, battery

power low or battery not
installed correctly

1. Not enough warm-up time

. Low gas pressure

3. Thermocouple loose or

needs to be replaced

4. Automatic control valve

needs to be replaced

5. Thermocouple gap is too

great

1. Low gas pressure

. Low fuel supply

3. Restriction in burner/orifice

elbow/hose and regulator
assembly

REMEDY

1. Open propane/LP supply

valve slowly

2. Clean burner/replace orifice

elbow/hose and regulator
assembly

3. Install new alkaline battery

in electronic ignitor. Verify
battery is installed correctly.
See page 1

1. Relight, hold automatic

control valve button in 30
seconds

. Check propane/LP cylinder

for proper gas supply

3. Tighten connection or re-

place thermocouple

4. Replace automatic control

valve assembly

5. Tip of thermocouple should

just touch the emitter mate-
rial. Loosen bracket screws
to move thermocouple clos-
er to burner. Be careful not
to allow ignitor to touch.
Maintain 0.0"

1. Check gas supply; check

regulator output

. Consult propane/LP gas

supplier

3. Clean burner/replace orifice

elbow/hose and regulator
assembly