Operation, Assembly – Desa TD100 User Manual

Page 7

Advertising
background image

www.desatech.com

118994-01G

7

Figure 9 - Connecting Hose/Regulator

Assembly to Propane/LP Cylinder

0 lb.
Propane/LP
Cylinder

Hose/Regulator
Assembly

OPERATION

CAUTION: Do not stand in

front of heater while lighting.

Stand at the side when lighting

the heater.

Use only a 0 lb. propane/LP cylinder (not
included). See safety information for proper
cylinder selection. Connect the hose/regula-
tor assembly to the cylinder (see Figure 9).
The hose should already be connected to the
heater. Connect hose to the valve inlet (see
Figure 9). Tighten firmly using a wrench.
Route retention chain through at least one
of the handles of the propane/LP tank (see
Figure 9). Make sure to route chain through
handle on tank and NOT around tank valve.
Chain must not interfere with valve. Attach
hooks on both ends of chains to chain retain-
ers installed on cabinet base (see Figure 8).

Figure 8 - Attaching Lightpost/Burner

Assembly to Cabinet Assembly

Lightpost/
Burner
Assembly

Cabinet
Assembly

Control
Valve Nut
and Control
Knob

ON/OFF
Switch

Ignitor

3. Connect white ground wire attached to

cabinet to right post on electronic ignitor.
Remove wire tie. Connect black ignitor
wire to left post on electronic ignitor. Install
battery in ignitor as shown on page 1.

4. Install batteries in battery holder as shown

on page 1. Do not mix batteries.

5. Connect regulator to gas cylinder, see

Operation. Gas cylinder will sit inside of
cabinet assembly.

6. Check for leaks. See Checking for Leaks

page 8.

7. Attach fourth lightpost panel to assembly with

6 screws (H) as shown in Figure 7, page 6.

Retention
Chain

ASSEMbLy

Continued

HEATER ASSEMBLY

Note: If needed, acquire assistance lifting
assembly.
1. Place entire lightpost assembly on top

of cabinet base assembly. Attach with 4
screws (H) as shown in Figure 8. Install
 screws (H) into holes on each side of
control valve. Attach control valve nut and
control knob to control valve.

. Connect  brown wires to ON/OFF switch.

Chain
Retainer

Control
Valve

Valve Inlet

Advertising