SLQV

Contact Closure

- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure

LED 1
LED 2
LED 3

LED 4
LED 5

CONTACT CLOSURE
INPUT

Any contact closure input whilst
the mechanism is in motion will
stop the movement and all other
contact closure commands will
be disabled for 1 second.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

PIN 2 NOT USED

G

O

3

GROUND

GROUND

W/O

W/G

4

PIN 4 NOT USED

BL

BL

5

DEVICE LEFT

Momentary short to GROUND (pin 3), will

make device go LEFT.

W/BL

W/BL

LED 4

6

DEVICE RIGHT

Momentary short to GROUND (pin 3), will

make device go RIGHT.

O

G

LED 3

7

DEVICE HOME

Momentary short to GROUND (pin 3),

makes device go OUT / HOME.

W/BR

W/BR

LED 2

8

DEVICE IN

Momentary short to GROUND (pin 3),

makes device go IN.

BR

BR

LED 1

PIN

DESCRIPTION

ACTION

WIRE / CABLE

CONTACT CLOSURE

LED INDICATOR