UBLS - Under Bed Lift Swivel

Operation Details

DC1
Low voltage power output for motor drive.
LED’s to show operation of limit switches
and positional counters

Mains Voltage Input

IR LED

IR Input Jack

RS232

Contact Closure























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return (Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND

PROTOCOL

ACTION

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

UBLS OUT no movement to swivel

fa_right Carriage Return (Enter )

UBLS OUT RIGHT limit

fa_left Carriage Return (Enter )

UBLS OUT LEFT limit

fa_preset Carriage Return (Enter )

UBLS to PRESET memory position

fa_stop Carriage Return (Enter )

STOPS the device at any position