ET / ET60 - Electric Tilt Mechanism

Operation Details

AC1
Gives an output of 240V
(or 110V).
AC2
Outputs stay live for 120
seconds after the OUT or
IN functions are selected.

EMERGENCY STOP
This connection will stop all
functions of the mechanism once
broken / removed. This is where we
recommend wiring a safety device -
For a range of safety devices see
control, safety & accessories section
in product brochure.























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly
as written, including Carriage Return
(Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND

Protocol

Action

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

Device OUT

fa_stop Carriage Return (Enter )

Device STOP (At any position)