Dmx connection, Signal wiring, Dmx junction box wiring – ILUMINARC Ilumipanel™ 180 IP User Manual

Page 5: Dmx cable table, Ilumipanel 180 ip optic rgb qrg

Advertising
background image

Ilumipanel 180 IP Optic RGB QRG

5

DMX

Connection

This product provides a DMX 512 connection by using bare-ended,
IP67-rated signal cable. This cable comes connected to the product.

Signal Wiring To provide the signal, you have two options:

·

Connect the bare-ended, IP6- rated signal cable from the product
to two IP67-rated signal connectors (DMX In and DMX Out).

·

Use an IP67-rated junction box. If so, make sure to use
IP67-rated conduit.

The signal cable must match or exceed the electrical characteristics of
the Belden® 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.

DMX Junction Box

Wiring

















DMX Cable Table Connection

DMX In

DMX Out

IP67 Pin

Ground

Shield

Shield

1

Data -

Black

Green

2

Data +

White

Red

3


Advertising