Installation

8

Ilumipod™ 36g2 IP User Manual Rev. 2

The Ilumipod™
36g2 IP must be
linked using DMX
cable in a daisy

chain (serial) fashion. To
comply with the EIA-485
standard, no more than
32 products should be
connected on one daisy
chain without using a
DMX optically isolated
splitter. Doing otherwise
may result in deterioration
of the digital DMX signal.

USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last product) to 300–455
m (985–1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the

electrical characteristics
of the Belden® 9841
cable for EIA RS-485
applications. You may
also use CAT5, 5e, or
CAT6 LAN cable.

DMX Linking

You may link the Ilumipod™ 36g2 IP to a DMX controller using a standard DMX serial
connection. If using other DMX products compatible with the Ilumipod™ 36g2 IP, you can
control each individually with a single DMX controller.
If you are not familiar with the DMX standard, or if you need information about the DMX
cables needed to link the Ilumipod™ 36g2 IP to a DMX controller, you may download the
DMX Primer from the ILUMINARC® website at

http://www.iluminarc.com/reports/dmx-

primer

.

DMX Modes

The Ilumipod™ 36g2 IP uses the standard DMX data connection for all of its DMX
personalities. Refer to the

Introduction

chapter for a brief description of these modes. Refer to

the Operation chapter to learn how to configure the Ilumipod™ 36g2 IP to work in these
modes. The

DMX Values

section provides detailed information regarding the DMX modes.

DMX Mode DMX Address DMX Mode DMX Address DMX Mode DMX Address

SOLID

512

ARC2

509

SPECIAL2

504

ARC1

510

ARC2+D

508

ARC1+D

509

ARC FULL

506

Signal Wiring

To provide signal for the Ilumipod™ 36g2 IP, you can connect the bare-ended,
IP67-rated signal cable from the product to two IP67-rated signal connectors (DMX In/DMX
Out) or use an IP67-rated junction box. In this case, make sure to use

IP67-rated conduit.

Protocol Connectivity

The Ilumipod™ 36g2 IP uses the USITT DMX 512 protocol The procedure below illustrates
the recommended connection method.




















Advertising
This manual is related to the following products: