17

104821

OWNER’S MANUAL

REPLACEMENT
PARTS

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealer from whom you
purchased this product. If they are unable to
supply original replacement part(s), call
DESA International’s Technical Service De-
partment at 1-800-323-5190 for information.

When contacting your dealer or DESA In-
ternational, have ready:

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural

gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

PARTS NOT UNDER
WARRANTY

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. When calling DESA Interna-
tional, have ready:

• model number of your heater

• the replacement part number

SPECIFICATIONS

VP1600TB

VP2600TB

Btu

16,000

26,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure* (in. of water)

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

Heater

22

30

Shipping

27

36

Note

: Dimensions listed are outer most points on the heater (includes control knobs

and grill).

* For purposes of input adjustment.

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner(s) will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner(s) will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

SERVICE HINTS

SERVICE
PUBLICATIONS

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting. If
so, contact DESA International’s Technical
Service Department at 1-800-323-5190.

You can also visit DESA International’s
technical service web site at

www.desatech.com.