Appendix “a – Pinnacle Systems MG User Manual

Page 34

Advertising
background image

The Diagnostics Display has two modes of operation:

Status and Fault. If a fault occurs, the display will scroll

the fault message until the “FN1” fault reset button is

pushed, even if the cause of the fault is corrected and/

or you reset the power.

Status Display Messages

Normal Operation

TEST

Testing internal systems

RST

Unit waiting for Push of RESET button

(located on control module power supply

board middle left hand side). If you push

the Reset button during normal operation,

the unit will go RED and display RST, push

again and the unit will start up.

RDY

Normal operation, no operations selected.

RdyE

External relay checking feature active

RdyM Mute-Out option enabled
RdyL

Normal, Latching Relay option software

selected. Used to reset guard penetration.

RdyF

Weld flash enabled

Obstruction

03 >

This is an example of 15 or more beams

blocked starting at 3” up from connector

pylon.

153

This is an example of 3 beams out starting

1.5” up from connector end of pylon.

SBLK Slave miroprocessor detected blockage

when the Master did not. Some of the

receiver signals are so weak that the

leading edge of the pulse is missed by the

Slave, but the trailing edge is not missed

by the Master. Realign the pylons.

FLIP

Master microprocessor is getting intermittent

blockage of the curtain, due to weak signals

and is flip-flopping between trying to go

GREEN and to RED. Re-align the pylons.

Floating Blank

FBxy

Floating Blank, x indicates # of beams

floating and y indicates option selected or

number of beams broken. Yellow LED on

the control unit will also light up.

OBST Floating Blank Obstruction; more than

one object was detected in the curtain.

Optional configuration allows two objects

for applications where the piece part is bent

twice.

Auto Blank

ABxy

Auto Blank, x indicates number of beams

blanked by object, y indicates option

selected or number of beams broken in

Mode 3. If no object found during program,

the display will read RDY.

In future software versions, the blocked

pattern will be stored in permanent memory

to allow you to power down without having

to reprogram in the object.

PENT Auto Blank in Mode 1 and/or Resettable

Latching Relay option in which the curtain

was penetrated. By moving the AB

keyswitch into OFF/RESET, you can clear

this but by moving the keyswitch into MODE

2 or 3 you can clear the PENT without

reprogramming in the AB object.

If using the Resettable Latching Relay

option, you can reset the cycling the

CLOSE contacts S5 located on the door of

the control unit. This is where you would

connect your remote reset push button.

SIZE

Auto Blank programmed object exceeded

eight beams total. Optional configuration

can increase or decrease this number.

MOVE Auto Blank object moved during normal

operations, exposing beams that were

previously blocked. This can occur if the

object is not fully blocking one of the beams

its covering. Optional configuration can

ignore movements of the object.

Mute-Out

MUTE Guard has gone into by-pass mode

Cincinnati Interface

CINN

When your Cincinnati interface applies

+24VDC to terminals 5 & 6, the curtain wil

go RED.

Appendix “A”

Diagnostics and Troubleshooting

A-2