Site requirements

Operating environment

•

Relative humidity: 20% to 80% non-condensing

•

Temperature: 60° F to 95° F (15° C to 35° C)

Electrical requirements

•

The external power supply is rated at 100-240 VAC, 50-60 Hz,
1.8 amp. (It adjusts to any power within this range.)

•

Single phase, 3-wire, grounded receptacle only.

Physical requirements

•

The printer weighs less than 11.5 pounds (5.3 kg). The weight
depends on the supplies and options installed.

•

Printer dimensions are 21.5 inches (546 mm) long and 7.8
inches (198 mm) wide. The 100-card input hopper is 9.5 inches
(241 mm) high and the 200-card hopper is 11.9 inches (302 mm)
high.

•

The clearance required 1 inch (25 mm) at the back, 2 inches (5
cm) on the left side, and 10.5 inches (267 mm) above the printer
latch to open the cover.

Do not use the printer in a dirty environment. Do not use the printer
in a closed compartment. Do not block air flow around the printer.

9.5”

11.9”

10.5” (for cover)

7.8”

2”

1”

21.5”