2. Set the desired power range by using the push-button switch on the
front panel labeled
POWER 300W/30W
. With the switch in the out
position, the
30W
range is selected. When the switch is locked in,
the
300W
range is selected.
3. The Peak Reading feature may be switch on/off by using the push-
button switch labeled
POWER PEAK/AVG
. Peak reading is
activated when the switch is locked in.
4. SWR is indicated at the intersection of the two meter pointers.
While transmitting, read the SWR from the red SWR line nearest the
intersecting point.
There is a fair amount of dissipation in the coupler (8W) at 300 watts
on any band. Operation at this power level must be held to a short time
(typically 1-2 minutes). If you see the meter register changes in reverse
power, this indicates that the special diodes are changing in forward
drop and that the high power should be removed. After a reasonable
amount of time, the wattmeter can be used again.
TECHNICAL ASSISTANCE
If you have any problem with this unit first check the appropriate
section of this manual. If the manual does not reference your problem
or your problem is not solved by reading the manual you may call
VECTRONICS at 601-323-5800. You will be best helped if you have
your unit, manual and all information on your station handy so you can
answer any questions the technicians may ask.
You can also send questions by mail to VECTRONICS, 1007 HWY 25
South, Starkville, MS 39759 or by FAX to 601-323-6551. Send a
complete description of your problem, an explanation of exactly how
you are using your unit, and a complete description of your station.