Configuration: Subcode 1 = 123
Received message: “70141231Hello World”
Relay response: Relay enabled
Serial output: “Hello World”

7.2.

Internal Function Commands (Global Annunciation)

The Internal Function Command field, associated with each address, is used to enter 7xxx output control
commands to be executed upon recognition of the RCD-1’s capcode (address). When configured, the
command corresponding to the capcode (FLEX model) or capcode/function bits (POCSAG model) is
executed as soon as the Capcode match is recognized. Any text following any output control code in the
received message will be output through the serial port. In the POCSAG model of the RCD-1, there are
four function code command entries corresponding to the four possible POCSAG function bit combinations.
If an entry is left blank, or disabled, no relay control command will be executed upon reception of that
function code. When only one response is desired, regardless of function code, all four function code
entries per capcode should be set to contain the same 7XXX command value.

This feature provides the ability to automatically annunciate the output of all message text on the serial port
using the relay output. The common application of this feature is to cause a horn and/or strobe to sound
each time a new message is displayed on an LED message board.