Side View

Front View

Figure 12 - Installing Bottom Mounting

Screws

Wall

Spacer

Heater

Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These

holes are near bottom on back panel of heater

(see Figure 12).

2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into

hollow or solid wall, install wall anchors.

Follow steps 1 through 4 under Attaching To

Wall Anchor Method, page 10.

If installing bottom mounting screw into wall

stud, drill holes at marked locations using

9/64" drill bit.

5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes

and wall anchor or drilled hole.

7. Hold spacer in place with one hand. With other

hand, insert mounting screw through bottom

mounting hole and spacer. Place tip of screw

in opening of wall anchor or drilled hole.

8. Tighten both screws until heater is firmly

secured to wall. Do not over tighten.

Note:

Do not replace front panel at this time.

Replace front panel after making gas connec-

tions and checking for leaks.

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 3/8" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

WARNING: For natural

gas, never connect heater to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

IMPORTANT:

For natural gas, check gas line

pressure before connecting heater to gas line. Gas

line pressure must be no greater than 10.5 inches of

water. If gas line pressure is higher, heater regula-

tor damage could occur.

CAUTION: For propane/LP

gas, never connect heater di-

rectly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between the

heater and propane/LP supply.

For propane/LP gas, the installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

the external regulator with the vent pointing down

as shown in Figure 13. Pointing the vent down

protects it from freezing rain or sleet.

Figure 13 - External Regulator With Vent

Pointing Down

External
Regulator

Propane/LP
Supply Tank

Vent
Pointing
Down