Desa DVFFBK User Manual

Desa Fans

Advertising
background image

installation instructions

For BloWEr Kit MoDEl DVFFBK

WARNING: Disconnect all electrical power to the

fireplace. Be careful of burrs and sharp edges.

BLOWER ASSEMBLY INSTALLATION

1. To remove lower louver, pull both top spring latches toward

the center of the appliance at the same time until they are

disengaged from the locating holes. Repeat for bottom spring

latches and pull louver outward.

2. Place blower assembly so it rests flush against the inside

wall on the flue exit side of the firebox (see Figure 1). There

are four magnets on the bottom of the blower assembly that

will keep the blower in place on firebox bottom. Note: If the

blower kit is not installed flush against the inside side wall of

the fireplace, the circulating air from the blower system will

not flow properly.

BLOWER SpEEd cONTROL OpERATION

1. To operate blower, turn the blower speed control knob

clockwise to the ON position (see Figure 3). This will be

the highest blower speed. Continue turning knob clockwise

to reduce blower speed. Turn knob only within the specified

range (1/4 revolution, see Figure 3).

2. To turn blower off, turn blower speed control knob counter-

clockwise until it clicks into the OFF position. You must turn

until knob clicks for the unit to be completely off.

Figure 1 - Blower Assembly Placement

Blower
Assembly

WIRING dIAGRAM

Figure 2 - Blower Speed Control Location

Glass

Speed
Control

Spring Latch

BLOWER
SPEED
CONTROL

BLOWER
ASSEMBLY

BLK (16 ga.)

BLK (16 ga.)

Wire Connectors 3 Places

Figure 4 - Wiring Diagram for Blower Assembly

Magnet

High Speed ON/OFF

Low
Speed

Magnets

1/4 Revolution

107514-01
REV. B
02/06

2701 Industrial Drive
PO Box 90004
Bowling Green, KY 42102-9004

NOT A UPC

Figure 3 - Blower Speed Control

Blower Center to
Firebox Bottom
Center Along Inside
Wall by Flue Exit

Peninsula or See-Thru
Fireplace Installed

Flue
Exit

For more information visit www.desatech.com

107514 01

Inside
Wall

BLOWER SpEEd cONTROL INSTALLATION

1. Place speed control switch assembly on the bottom of the inside of

the firebox (see Figure 2). The assembly is equipped with magnets

on the left and right to properly anchor it to the firebox.

2. Plug blower with speed control assembly into a power source.

Keep hands clear of fan when running.

Advertising