Command Réponse Type

Nom

MIN

MAX

Description

Values

Modif

#

#

Rd/Wr

DIESE

0

1

ask for sending all variables (to refresh
values of all variables)

?

DEV

Rd

DEV

0

65535 Unit Type (OXE = 41)

0 unknown unit
41 (0x29) OXE
42 (0x30) OVF831 Octo Vue Fade
43 (0x31) OVP831 Octo Vue
44 (0x32) OFX803 Octo FX II
45 (0x33) OFD803 Octo Fade II
46 (0x34) OCP803 Octo Plus II
47 (0x35) QVP421 Quattro Vue
48 (0x36) QFX402 Quattro FX
49 (0x37) QTD402 Quattro D
50 (0x38) QTA401 Quattro
70 (0x46) QVX421 Quattro Vue FX

yU

yU

Rd/Wr

UPDATER

0

255

Reset of the unit for Update

1 puis 254 -> reboot

yo

yo

Rd

OPT

0

65535 Options detected

0=Option LAN

PP

PP

Rd/Wr

PPROC

0

1

VCR video mode(video tape recorder)

0 stable source (DVD.)
1 VCR source (noisy picture)

PV

PV

Rd/Wr

PVISC

0

1

Activate commutation in the screen

0=standard commutation
1=screen commutation

LM

LM

Rd/Wr

LMODE

0

6

LOGOS using mode

0 normal mode (use)
1 recording logo mode
2 recording animated logo mode
3 recording frame mode
4 erase logo mode
5 erase frame mode
6 transfert logo mode

LI

LI

Rd/Wr

LINFINDEX

0

255

Index to recover information about
logo/Frame

Logo : number of the listed logo
Frame : 100+number of the Frame

Ly

Ly

Rd

LINFPIXELSIZ

0

65535 Info du nombre de pixels dans la ligne de

la Frame/Logo

TB

TB

Rd

TBAR

0

4095

% of the effect status

RAZ auto

Advertising