Examples, 5 examples, Programmer's guide for orchestra – Analog Way ORCHESTRA2 Programmer's Guide User Manual
Page 5

5
PROGRAMMER'S GUIDE FOR ORCHESTRA
2
v04.00 build 52
PRESET
CONTROL
Command Answer
Description
Access
Min
Max
Index 1
Index 2
Index 3
Value
SF
SF
Screen Filter
(Disable / Enable
Preset Load and Take
per Screen)
Read
Write
0
1
0 = Screen1
...
5 = Screen6
1 = Enabled
TK
TK
Take as soon as
devices are ready
Read
Write
0
1
1 = Take >> 0 when
completed
OLD
Command Answer
Description
Access
Min
Max
Index 1
Index 2
Index 3
Value
PF
PF
! Obsolete !
= SF command
Read
Write
0
1
0 = Screen1
...
5 = Screen6
1 = Enabled
5 EXAMPLES
Write command
Answer
Description
Value
Characters
10
PL
PL10<CR><LF>
Load the Preset Memory #10
Write command
Answer
Description
Index
Index
Index
Value
Characters
2,
2,
4,
6
SS
SS2,2,4,6<CR><LF>
Put the source #6 into the 5th PIP of screen #3
Read command
Answer
Description
Character
?
DEV77<CR><LF>
Get the Device Type (77=ORC50)
Read command
Answer
Description
Index
Characters
0,
rS
rS0,1<CR><LF>
Get the status of screen#1 (1=Ready)