Analog Way PULSE LE - Ref. PLS200 Programmer's Guide User Manual
Page 23

23
Group
Name
CmdResp Description
Read
/
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
SET_HUE
Su Su
Input hue (NTSC only)
Rd/Wr0
255 128
128 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_HTOTAL
ST ST
Input total pixel per line
Rd/Wr0
655350
Unit = pixels.
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_PHASE
SS SS Input Phase
Rd/Wr0
31
16
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
SET_AUTOCAD
Sa Sa
Input autocentering reques
Rd/Wr0
1
0
Auto reset
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12