Group

Name

CmdResp Description

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SET_HTOTAL

ST ST

Input total pixel per line

Rd/Wr 0

65535 0

Unit = pixels.

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_PHASE

SS SS Input Phase

Rd/Wr 0

31

16

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_AUTOCAD

Sa Sa

Input autocentering reques

Rd/Wr 0

1

0

Auto reset

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SET_USER_GAIN_R

sr

sr

ADC R channel adjustment
(advanced setting)

Rd/Wr 0

255

128

128 = neutral

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
8 = Input9
9 = Input10
10 = Input11
11 = Input12