14

Group

Name

Cmd Resp Description

Read /
Write

Min
value

Max
value

Default
value

Values

Index #1

Index #2

IN_KEYING_INVERT

KI

KI

Invert keying area

Rd/Wr 0

1

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12

IN_KEYING_GRAB_ENABLE

Kg

Kg

Enable/disable the keying color
grabber mode

Rd/Wr 0

1

0

0 = Disable the grabber
1 = Enable the grabber

IN_KEYING_GRAB_GET

Kc

Kc

Capture the coolor selected by
the grabber and apply the
settings

Rd/Wr 0

1

0

Percent of OSCREEN_UTIL_H

IN_KEYING_GRAB_H

Kh

Kh

Horizontal position of the grabber Rd/Wr 0

65535 32768 Precent of OSCREEN_UTIL_V

IN_KEYING_GRAB_V

Kv

Kv

Vertical position of the grabber

Rd/Wr 0

65535 32768 Auto reset

INPUT
STATUS

SIG_HPOL

sh

sh

Input H sync polarity

Rd

0

1

0

0 = Negative Synchro
1 = Positive Synchro

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12

SIG_VPOL

sv

sv

Input V sync polarity

Rd

0

1

0

0 = Negative Synchro
1 = Positive Synchro

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
8 = Input9
9 = Input10
10 = Input11
11 = Input12