95

Code-11

Read: Format

Data Digits

(Variable)

Checksum1

(Optional)

Checksum2

(Optional)

Checksum Verification: The checksum is presented as the

sum module 11 of all data digits.

Checksum Transmission: By setting Enable, checksum1

and checksum2 will be transmitted upon your selected

checksum verification method.

Max./Min. code length: Refer to Max./Min. code length of

Code-39.

Truncate leading/ending: Refer to Truncate leading/ending

of UPCA.

Code ID setting: Refer to Code ID setting of UPCA.

Insertion group number selection: Refer to page 57

th

Insertion group number selection of UPCA.

Option Bar Code

Option

Alphanumeric

Entry

Read

Disable

Enable

00

*

01

Checksum

Verification

Disable

One digit

Two digits

00

01

*

02

Program