API_SaveSettingsToFile

To Save current scanner settings to file. The extension file name is “axs”.

BOOL API_SaveSettingsToFile

{

LPCTSTR

filename

}

Parameters

filename

[in] file name of the scanner settings.

Returned Values

Returning TRUE if the operation is successful, otherwise, return FALSE.

Example

CString strFile;

CfileDialog dlg(FALSE, _T("axs"), NULL, OFN_CREATEPROMPT, _T("Scanner Settings Files (*.axs) |*.axs ||

"));

if(dlg.DoModal() != IDOK)

return;

strFile = dlg.GetPathName();

if(API_SaveSettingsToFile(strFile))

AfxMessageBox(_T("Save to file Succeed"));

else

AfxMessageBox(_T("Save to file Fail"));

Requirements

OS Versions: Windows CE 6.0 or beyond.

Header: scanapiax.h

Link Library: scanapiax.lib

Link DLL: scanapiax.dll