New wall construction, Existing fireplace – Dimplex BF8000ST User Manual
Page 9
 
9
New Wall
Construction
1. Select a suitable
location that is not
susceptible to moisture
and is away from
drapes, furniture and
high traffic.
2. Place the fireplace in
the desired location to
see how it will look in
the room.
3. Mark the desired
location on the floor.
4. Use studs to frame an opening of 26 ¾ inch (679 mm) wide x 23 ⅛
inch (587 mm) high x 9 inch (229 mm) deep.
Option #1: The power cord can be run from behind the trim and
along the wall to an outlet near the fireplace.
Option #2: A new outlet can be installed inside the framing
construction.
Plug the unit into a 15 Amp, 120 volt outlet. If the cord does not reach,
you may use an extension cord rated for a
minimum of 1875 Watts.
Existing Fireplace
1. Seal all drafts and vents with a non-fibrous insulation material to
prevent any chimney debris from falling onto the fireplace. Do not
	 install	into	an	existing	fireplace	that	is	prone	to	dampness.
2.	 Cap	the	top	of	the	chimney	flue	to	prevent	rain	from	entering.
3.	 Plan	your	electric	power	supply.
4.	 The	power	cord	can	run	along	the	front	of	the	hearth	to	an	outlet	
near the fireplace.
CAUTION: Clearance for air circulation beneath the fireplace insert
is provided by two spacers.
Do not install the fireplace insert
26 ¾”
(679 mm)
23 ⅛”
(587 mm)
9”
(229 mm)
Figure 5