2 power requirements, Hardware preparation and installation – Artesyn XMCspan Installation and Use (June 2014) User Manual
Page 18

Hardware Preparation and Installation
XMCSPAN Installation and Use (6806800H03C)
18
2.2
Power Requirements
The XMCspan uses only +5.0 V from the VMEbus backplane. On-board power supplies
generate the required voltages for the various ICs. The XMCspan connects the +12 V and -12 V
supplies from the backplane to the PMC sites while the +3.3 V power supplied to the PMC sites
comes from the +5.0 V backplane power. A maximum of 15A of +3.3 V power is available to the
PMC sites, however the 90 W +5.0 V limit must be observed as well as any cooling limitations.
Requirement
Operating
Non-Operating
Temperature
0°C (32°F) to +55°C (+131°F)
This may be limited by the type of
hard disk used.
-40°C (-40°F) to +85°C (+185°F)
Temperature Change
+/-0.5°C/min
+/- 1°C/min
Forced Air Flow
-
-
Relative Humidity
5% to 95% non-condensing at
+40°C (+104°F)
5% to 95% non-condensing at
+40°C (+104°F)
Altitude
-300m to 3,000m
-300m to 13000m
Vibration
0.1g from 5 to 100 Hz and back to
5Hz at a rate of 0.1 octave/minute
5-20 Hz at 0.01 g2/Hz
20-200 Hz at -3.0 dB/octave
Random 5-20 Hz at 1 m2/Sec3
Random 20-200 Hz at -3 m/Sec2
Shock
Half-sine, 5g/11ms
Half-sine, 15g/11ms
Free Fall
100 mm/3 axis
1,200 mm/all edges and corners
(packaged)