Portable air compressor, Maintenance – Westward 3JR70A User Manual

Page 13

Advertising
background image

Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

13- ENG

Maintenance

CUSTOMER RESPONSIBILITIES

Daily

or after

each

use

Before

each

use

Check Safety Valve
Drain Tank

NOTE: See "Operation" section for

the location of controls.

Unit cycles

automatically when

power is on. When performing

maintenance, you may be exposed

to voltage sources, compressed air,

or moving parts. Personal injuries

can occur. Before performing any

maintenance or repair, disconnect

power source from the compressor

and bleed off all air pressure.

TO CHECK SAFETY VALVE

If the safety valve

does not work

properly, over-pressurization may

occur, causing air tank rupture or

an explosion.

1. Before starting compressor, pull

the ring on the safety valve to

make sure that the safety valve

operates freely. If the valve

is stuck or does not operate

smoothly, it must be replaced

with the same type of valve.

TO DRAIN TANK
1. Set the On/Auto/Off lever to

"OFF".

2. Turn the regulator knob

counterclockwise to set the outlet

pressure to zero.

3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing

air to bleed from the tank until

tank pressure is approximately 20

psi. Release safety valve ring.

5. Drain water from air tank by

opening drain valve (counter-

clockwise) on bottom of tank.

Water will

condense in the

air tank. If not drained, water will

corrode and weaken the air tank

causing a risk of air tank rupture.
6. After the water has been drained,

close the drain valve. The air

compressor can now be stored.

NOTE: If drain valve is plugged in,

release all air pressure. The valve

can then be removed, cleaned, and

reinstalled.

Advertising