Plasma television screens generate infrared interference. It is not recommended to use a plasma

display in the same room where the TLD100 is installed.
However, if a plasma screen must be used, install it in the following way and after confirming
operation, use it very carefully.

①

Install the infrared sensor in a location where side and back of plasma display cannot be seen, and install it as far

away as possible (more than 10 m {33 feet}).

②

The distance between the infrared sensor and microphone should be as short as possible (within 3 m {10 feet})

while in use.

③
④

Do not put any blocks (including the human body) between the infrared sensor and microphone while in use.

Even after following these recommendations, interference may still occur.

•

The distance between a fluorescent lamp and the infrared sensor should be as far apart as possible

(more than 1 m {3.3 feet}) in installing.

•

If a remote controller such as an audio-visual device or air conditioner is controlled by an infrared

sensor, noise or sound breaks may occur.

•

If there are any other devices making strong noises, product may sometimes be impossible to use.

In that case, install the product farther away until it can be used.

•

Ceiling height is expected to be 2 m {7 feet} to 4 m {13 feet}. If it is out of this range, the arrival range

may be shortened.

•

The base color of wall, floor, and ceiling should be white or light colors. With black or dark color

surfaces, the arrival range may be shortened.

•

A reflection from the wall is used in the arrival range. If the wall is far away from the area of use, the

arrival range may be shortened.

•

Sound breaks may occur near windows or in rooms with a lot of windows. In this case, it may be

useful to use light-colored curtains or window shades.

•

If a microphone is used near and facing a wall, sound breaks may occur.

•

For tightening bolts and screws, pay attention to the following points:

①

Torque control is necessary for tightening the bolts and screws.

②

Torque wrench and torque driver are necessary for controlling the torque.

③

Never use any impact driver or electric drill because torque control is difficult even if they have a clutch. Their use

may result in damage to the mounting part.

•

After mounting, confirm visually that the product is firmly and stably fixed. If the product is properly

installed, it will not wobble or make noise.

•

In installing this infrared sensor, be aware of the following:

①

Be sure that the installation is carried out by qualified personnel when installing at high locations.

②

Before installation, confirm that there is nobody around.

③

In order to carry out the installation safely and surely, pay close attention to the safety control.

•

The supplied safety strap shall be used.

Be sure to firmly secure the safety strap to the ceiling mount bracket at installation.

•

Precaution for installation place and securing of the conversion box:

The conversion box shall be installed on a stable place such as on a shelf and secured with screws as necessary.

•

Do not apply strong force to this unit. Failure to observe this may damage this unit.