Yearly Service Procedure

• Failure to inspect and maintain the stove may lead to improper combustion and a potentially

dangerous situation. We recommend the following procedures be done by a qualified technician.

1. Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor.

If it does not, contact your dealer for service.

2. Shut off gas to the stove and let it cool for 15 minutes. Remove the glass (see page 26).

3. Remove the media (NOTE: The logs are very fragile - see page 28). If severely deteriorated,

replace. Check the logs for sooting. A small amount of soot along the bottom of the logs is normal.
If excessive sooting is found, the stove will require adjustment. Contact your dealer.

4. Inspect the burner and remove any debris.

• Make sure the burner is not warped, cracked, or damaged.
• Check the firebox and area around the pilot to make sure there is no warping or damage.
• If any problem is found, discontinue use and contact your dealer for service.

5. Replace the media set. Clean and replace the glass. If the glass is damaged, replace. Make sure

the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal.
If it does not, re-align or replace the gasket to insure an air-tight seal.

6. Inspect the area behind the access door. Clean if necessary. Check the

gas control valve and the gas lines. If damage is found, discontinue use
and contact your dealer for service. Clean the air channels, ducts, and
blower (if applicable).

7. Start the main burner. Inspect the main burner and pilot flame. After 15

minutes the flames should be orange/yellow and not touch the top of the
firebox. If the pilot or main burners do not burn correctly, contact your
dealer for service. Monitor blower operation.

8. Remove any debris or vegetation near the vent termination. Contact

your dealer if any sooting or deterioration is found near the vent
termination. Venting system should be examined by a qualified agency.

Advertising