30 installation, Termination requirements – Avalon Firestyles Bed & Breakfast Installation User Manual

Page 30

Advertising
background image

30 Installation

(for qualified installers only)

Travis Industries

4140312

100-01305

Termination Requirements

!

Venting terminals shall not be recessed into a wall or siding.

A

Minimum 9" clearance from any door or window

B

Minimum 12" above any grade, veranda, porch, deck or balcony

C

Minimum 1" from outside corner walls
NOTE: Clearance in accordance with local installation codes and the requirements
of the gas supplier.

D

Minimum 1" from inside corner walls
NOTE: Clearance in accordance with local installation codes and the requirements
of the gas supplier.

E

Minimum 11" clearance below unventilated soffits or roof surfaces
Minimum 18" clearance below ventilated soffits
Minimum 6" clearance below roof eaves
NOTE: Vinyl surfaces require 24"
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

F

Minimum 12" clearance below a veranda, porch, deck or balcony
NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor.
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

G

Minimum 48" clearance from any adjacent building

H

Minimum 84" clearance above any grade when adjacent to public walkways or driveways
NOTE: may not be used over a walkway or driveway shared by an adjacent building

I

Minimum 9" clearance to any nonmechanical air supply inlet to the building or the combustion air inlet to any
other appliance.

J

Minimum 36" clearance above any mechanical air supply inlet if within 10’ horizontally

K

Minimum 36" from the area above the meter/regulator (vent outlet) - this extends 15’ above the regulator
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

L

Minimum 36" from the meter/regulator (vent outlet)
NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier.

M Minimum 12” above the roof line (for vertical terminations)

N

Minimum 24” horizontal clearance to any surface (such as an exterior wall) – for vertical terminations

•

Use the vinyl siding standoff when installing on an exterior with vinyl siding.

•

Vent termination must not be located where it will become plugged by snow or other material.

11” Min.

6” Min.

Roof
Surface

Roof
Eaves

C

B

H

E

G

A

D

F

L

K

J

I

NOTE: Measure clearances to the nearest edge of the exhaust hood.

A

E

E

M

N

Advertising
This manual is related to the following products: