Storing, transporting, or shipping, Preventative maintenance schedule – Desa RM200T User Manual

Page 6

Advertising
background image

6

103607

PORTABLE FORCED AIR HEATER

200,000 BTU/HR

Item

Fuel tank

Air output and
lint filters

Air intake filter

Fuel filter

Spark plug

Fan blades

Motor

WARNING: Never service

heater while it is plugged in, op-
erating, or hot. Severe burns and
electrical shock can occur.

STORING,
TRANSPORTING,
OR SHIPPING

Note:

If shipping, transport companies re-

quire fuel tanks to be empty.

1.

Drain fuel tank.

Note:

This model has a drain plug on

underside of fuel tank. Remove drain
plug to drain all fuel. Be sure all fuel is
removed.

2.

Replace drain plug.

3.

If any debris is noted in old fuel, add 1
or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent
excess debris from clogging filters dur-
ing future use.

4.

Replace fuel cap and drain plug. Prop-
erly dispose of old and dirty fuel. Check
with local automotive service stations
that recycle oil.

5.

If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.

IMPORTANT:

Do not store kerosene over

summer months for use during next heating
season. Using old fuel could damage heater.

PREVENTATIVE
MAINTENANCE
SCHEDULE

How Often

Flush every 150-200 hours of operation
or as needed

Replace every 500 hours of operation or
once a year

Wash and dry with soap and water every
500 hours of operation or replace as
needed

Clean twice a heating season or replace
as needed

Clean and regap every 600 hours opera-
tion or replace as needed

Clean each season or as needed

Not required/permanently lubricated

How To

See Storing, Transporting,
or Shipping

See Air Output, Air Intake,
and Lint Filters,
page 8

See Air Output, Air Intake,
and Lint Filters,
page 8

See Fuel Filter, page 9

See Spark Plug, page 10

See Fan, page 8

Advertising