30 operating your appliance, Troubleshooting problem possible cause – Avalon Firestyles Small Flush Hybrid-Fyre User Manual

Page 30

Advertising
background image

30

Operating Your Appliance

© Travis Industries

100-01342

4150521

Troubleshooting

Problem

Possible Cause

Smoke Enters Room During
Start-Up

 Open the bypass (pg. 22).
 Open the air control (pg. 25).
 Cold Air Blockage - burn a piece of newspaper to

establish a draft.

 If the flame is not getting enough air, a small crack in

the door is all that is needed.

Kindling Does Not Start - Fire
Smolders

 Open the bypass (pg. 22).
 Open the air control (pg. 25).
 Not enough starter paper - use additional newspaper if

necessary.

 If the flame is not getting enough air, a small crack in

the door is all that is needed.

Smoke Enters Room While Re-
Loading

 Open the bypass before opening the door (pg. 22).
 Open the air control before opening the door (pg. 25).
 Let the air stabilize before fully opening the door.

Then open the door approximately 1 inch. Let air go
into the firebox for a few seconds. Once the smoke
appears to be flowing up the chimney consistently,
open the door.

 Insufficient Draft - Chimney height and outside

conditions can negatively affect draft. In these cases a
small amount of smoke may enter the home. Adding
more piping or a draft-inducing cap may help.

 Chimney liner joints are not properly sealed at the

insert connection.

Stove Does Not Burn Hot Enough

 Wood is Wet - see the section "Selecting Wood" on

page 28 for details on wood.

 Make sure the air control is all the way open. Slide the

control back and forth to insure the control is not stuck.

 Insufficient Draft - Chimney height and outside

conditions can negatively affect draft. In these cases
the fire may burn slowly. Adding more piping or a
draft-inducing cap may help.

Blower Does Not Run

 Stove is Not Up to Temperature - This is normal. The

blower will come on when the stove is hot - usually 15
to 30 minutes.

 Electricity Is Cut to the Blower - Check the household

breaker or fuse to make sure it is operable.

Stove Does Not Burn Long
Enough

 Depending upon wood, draft, and other factors, the

burn time may be shorter then stated. Make sure the
doors are sealing and not allowing air into the firebox -
See the section "Door and Glass Inspection" on page
32 for details.

 Check the ash bed for coals. Often, coals are still

glowing under a slight bed of flyash. By raking these
into a pile you can re-start your stove quickly.