Avalon Firestyles 700 B-Vent-1994 User Manual

Page 36

Advertising
background image

P

AGE

36

O

PTIONAL

E

QUIPMENT

(C

ONTINUED

)

Re-Routing the Power Cord to the Left or Rear of the Heater

The power cord is normally routed to the right side of the heater. It may be re-routed to the left, or if the
heater is installed as a stove, at the rear. The directions below detail this procedure.

1. TURN THE GAS LINE VALVE TO OFF AND UNPLUG THE HEATER (if the heater is

connected or plugged in).

2. Use slip joint pliers to remove the strain relief that holds the power cord in place (see the

illustration below).

Ashlip
Control
Housing

Power Cord

To remove the strain relief, use a pair
of slip joint pliers to press from the top
and bottom of the relief. Pull the relief
out once it becomes loose.

3. Open the access panel and with a 7/16" nutdriver loosen the three bolts that hold the control

housing in place. When the control housing becomes loose, lift it off the bolts and place it face
down in front of the heater. The wires that lead to the control housing can then be accessed.

Loosen these
three bolts with
a 7/16" nutdriver

Ashlip Control Housing

Access Panel

4. Disconnect the molex connector that attaches to the power cord. Remove the power cord from

the heater by threading the molex plug through the hole in the ashlip control housing (see the
illustration below). To route the power cord to the left side, follow step 5A. To route the cord to
the rear (stoves only), follow step 5B.

Blower
Rheostat

Disconnect the molex plug
to re-route the power cord.

Route the power
cord through this
notch in the
ashlip control
housing partition.

This hole if
for routing
the power
cord to the
rear of the
heater.