Inalizing the, Nstallation, Cont – Avalon Firestyles D-V-1996 User Manual

Page 28

Advertising
background image

P

AGE

28

F

INALIZING THE

I

NSTALLATION

(

CONT

.)

- For Qualified Installers Only!

3

Close the door. Make sure the door is centered and the attachment screws are tightened to form a
seal around the door opening.

4

Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.

5

Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.

The pilot flame should impinge the top 3/8” (10 mm)
of the thermopile. If it does not, you may need to
turn the pilot up.

3/8” (10 mm)

Thermopile

Pilot Hood

Thermocouple

To adjust the pilot flame, remove the cover screw (and
gasket) and turn the needle valve. Clockwise lowers
the flame while counter-clockwise raises it.

PILOT ADJ

T

O

L

PI

ON

OFF

Standard
Screwdriver

Micro (1/16”)
Standard
Screwdriver

The cover screw and
gasket must be
replaced to prevent gas
from leaking

Cover Screw

Cover Screw Gasket

Needle Valve

Advertising