Installation, Tile hearths, Mantel requirements – Avalon Firestyles DVS Fireplace EF-2001 to 2007 User Manual
Page 16: For qualified installers only) © travis industries, Combustible or non-combustible mantels

1 6
Installation
(for qualified installers only)
© Travis Industries
4041213
1 0 0 - 0 1 1 5 2
Tile Hearths
32 DVS Fireplace
Face
3/8" Thick
Tile, Marble,
or Granite
Two Layers of
1/2" Cement
Board
Wood Sub Floor
1-1/2"
Facing installs behind the face
Base of Fireplace
12" Min.
Min. 1-3/8"
Thick
Hearth
The front and side edges can be trimmed in various ways:
Min. 1-3/8" Thick Hearth
Bull-Nose Tile
(Cut to 1-3/8")
Edge Tile
(Cut to 1-3/8")
Wood Molding
(Cut to 1-3/8")
Mantel Requirements
•
The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it
is considered a mantel and must meet the mantel requirements listed in this manual.
Combustible or Non-Combustible Mantels
Combustible or Non-Combustible Mantel
Max. Mantel
Depth is 8”
Base of Fireplace
17
” Minimum
1-1/2”
See “Face Dimensions”
for face sizing.
Bottom of Faceplate