Vent location, Vent configurations, Nsert – Avalon Firestyles DVS Insert-1996 to 2000 User Manual

Page 10: Nstallation, Cont

Advertising
background image

P

AGE

10

I

NSERT

I

NSTALLATION

(

CONT

.)

- For Qualified Installers Only!

Vent Location

2-1/2"

(64 mm)

15-3/4"

(400 mm)

2-1/2"

(64 mm)

13-1/2"

(343 mm)

Center Line

13-1/4"

(337 mm)

Inlet (3Ó (75 mm) Dia.)

Exhaust (3Ó (75 mm) Dia.)

Fireplace

Opening

Vent Configurations

Z.C. (Metal) firebox

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

(recommended)

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

3" (75 mm)

UL 1777

Gas Liner

Dura-Vent Termination Kit

(part # 923GK)

The block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Exhaust

Inlet

Exhaust

Masonry Fireplace

Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.

Any cracks or
damage inside the
chimney must be
repaired.

Advertising