(for qualified installers only)

11

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

Approved Venting Configurations with a Horizontal Termination

•

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

•

The termination must fall within the shaded area shown in the chart. Use restrictor position #1.

Natural Gas (NG)
Installations

Propane (LP)
Installations

5 feet

0 feet

10' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

12 feet

(max)

NOTE:

A minimum 2 foot rise is required

directly off of the stove.

12 feet (max)

5 feet

10' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

5 feet

0 feet

11' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

NOTE:

A minimum 3 foot rise is required

directly off of the stove.

12 feet (max)

11' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

12 feet

(max)

5 feet