I n t e r p r e t e d Z P L I I ® C o m m a n d s

The following lists the ZPL II

 commands interpreted by the MONARCH 9906 printer’s MLI™.

Imaging

ZPL II

Cmds

Notes:

ZPL II

Cmds

Notes:

ZPL II

Cmds

Notes:

^A

^DF

We only support
downloading to RAM.

^IS

^A@

~DG

No rotation of graphics.

~JA

^B2

~DY

No rotation of graphics.

^LH

^B3

~EF

^LL

^B7

If the number of rows or
columns are not
specified, the bar code
size is different.

~EG

Graphics cannot be
erased from within a
format.

^LR

^B8

No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.

^FB

Use only for text
justification.

^LS

^B9

No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.

^FD

^LT

^BA

^FH

^MU

^BB

Supports CODABLOCK F

^FN

^PO

^BC

^FO

^RT

Does not read an RFID
tag, but is required if an
^HV command is used.

^BD

Supports modes 2, 3,
and 4.

^FR

^SF

^BE

No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.

^FS

^XA

^BK

^FT

The X and Y coordinates
must be specified.

^XF

^BL

^FV

This command works the
same as the ^FD
command.

^XG

No magnification.

^BM

The printer only uses
one mod-10 check digit.

^FW

^XZ

^BU

No interpretation line
(human readable
characters) when narrow
element is wider than 4
dots.

^F X

^B X

The bar code size is
different. Only use the
value of 200 for the error
correction level, no
rectangular symbols or
custom formats.

^GB

No support for rounded
corners.

^BY

^GF

No rotation of graphics.

^CF

^ID

~DB

No support for double-
wide character fonts.

^IL