Avery Dennison 7410 Network Card Addendum User Manual
Page 6

6
Additionally, the Path can contain any of the following options:
%IPA
The IP address is substituted for %IPA and dots (‘.’) are replaced
with dashes (‘-‘).
%MAC The MAC address is substituted for %MAC and dots (‘.’) are
replaced with dashes (‘-‘).
%PUC The value of a Power-Up Counter is inserted in place of %PUC. The
counter is set to zero when the printer is turned on or reset and
incremented each time a log file is sent to the host.
%DAT The current date is substituted for %DAT and slashes (‘/’) are
replaced with dashes (‘-‘). The format is YY-MM-DD.
%TIM The current time is substituted for %TIM and colons (‘:’) are
replaced with dashes (‘-‘). The format is HH=MM=SS.
%DNT The current date and time are substituted for %DNT and slashes (‘/’)
and colons (‘:’) are replaced with dashes (‘-‘). The format is
YY-MM-DD_ HH=MM=SS.
These options are useful to determine
♦
a printer’s IP address or location (perform a search).
♦
which file goes with a particular printer?
♦
when a log file was created based on time and/or date.
Example “Logs/PX_%IPA_%DAT.log”
generates a filename similar to:
“Logs/PX_192-0-0-192_06-03-20.log”