I/O

XFC

Application Note DK9222-0211-0021

This publication contains statements about the suitability of our products for certain areas of application. These statements are based on typical features of our products. The examp-
les shown in this publication are for demonstration purposes only. The information provided herein should not be regarded as specific operation characteristics. It is incumbent on the
customer to check and decide whether a product is suit-able for use in a particular application. We do not give any warranty that the source code which is made available with this
publication is complete or accurate. This publication may be changed at any time with-out prior notice. No liability is assumed for errors and/or omissions. Our products are described
in detail in our data sheets and documentations. Product-specific warnings and cautions must be observed. For the latest version of our data sheets and documentations please visit
our website (www.beckhoff.com).

© Beckhoff Automation GmbH, February 2011
The reproduction, distribution and utilisation of this document as well as the communication of its contents to others without express authorisation is prohibited. Offenders will be
held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.

Apart from the time-constant measurement of events by the time-stamped process data, actions are also executed at a
precisely defined time. Thus, parallel wired peripherals can be eliminated on test and experimental benches by means of not
initiating an action directly by a user intervention, but rather by the user ‘announcing’ it at an exactly defined process data
point/time.

The described relations are decisive for test benches in which a volume throughput per unit time is measured.

External reference time

PLC

Device
under
Test

Reference

Measured value

Calibration to ext. reference

EL1252

Fig. 6 Practical time stamp example: calibration to an external reference

– 2-channel digital input terminal with time stamp www.beckhoff.com/EL1252
– 2-channel digital output terminal 24 V DC with overexcitation www.beckhoff.com/EL2212
– 2-channel digital output terminal with time stamp, tri-state www.beckhoff.com/EL2252
– XFC: The new class of Control Performance www.beckhoff.com/XFC
– EtherCAT www.beckhoff.com/EtherCAT

New Automation Technology

Beckhoff