3.3.3 Floppy interface

A floppy drive can be attached in one of two alternative ways: One is a standard 2x17-pin connector (FCI
75869-306LF) for ribbon cables, the other is a 26-pin connector (JST 26FMZ-BT) for Flat Flex cables
(FFC).

C

AUTION

The two connectors can only be used one at a time.

Pinout FFC connector (FDD):

Pin

Name

Description

1

VCC

5 volt supply

2

IDX#

index

3

VCC

5 volt supply

4

DR0#

drive sel 0

5

VCC

5 volt supply

6

DC#

disk change

7

N/C

reserved

8

N/C

reserved

9

N/C

reserved

10

MT0#

motor enable 0

11

N/C

reserved

12

DIR#

direction

13

N/C

reserved

14

STP#

step

15

GND

ground

16

WD#

write data

17

GND

ground

18

WE#

write enable

19

GND

ground

20

TR0#

track 0

21

GND

ground

22

WPRT#

write protect

23

GND

ground

24

RDATA#

read data

Advertising