Pecifications, Heating specifications, Dimensions – Dansons Group CC3 User Manual

Page 8: Electrical specifications, Fuel considerations, Epa compliance

Advertising
background image

Copyright 2005

8

Vulcan V SERIES

Owner’s Manual

Canadian Comfort Industries

www.stovesunlimited.com

Dansons Group Inc.

S

PECIFICATIONS

HEATING SPECIFICATIONS

- Approx. Heating capacity (Sq Feet) ¹

= 800 – 2,000 sq ft

- Approx. Fuel burn rate per hour ¹¹

= 1.75 – 5.5 lbs per hour

- Hopper Capacity

VULCAN “V” Series V130

= 55 pounds

- Hopper Capacity

VULCAN “V” Series V150

= 120 pounds

¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the

outside temperature. Fuel size, quality, density and moisture level will also have an effect.

¹¹ Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as

20%. Use PFI listed fuel for best results.

DIMENSIONS

ELECTRICAL SPECIFICATIONS

Electrical Rating

= 115 Volts 60 HZ 2.0 Amps

Watts (operational)

= 175 (approximately)

Watts (optional igniter)

= 475 (approximately)

A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit board
will be voided if surge protection is not installed before operating this unit.

FUEL CONSIDERATIONS

Your

VULCAN “V” Series

shop and home heater, is designed to burn pellets that comply with Association of Pellet

Fuel Industries standards. (Minimum of 40lbs density per cubic ft, ¼ to 5/16’ diameter length no greater than 1.5”,
not less than 8,200 BTU’s/lb, moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per
million) Pellets that are soft, contain excessive amounts of loose sawdust, have been or are wet, produce clinkers
and/or heavy ash will result in reduced performance and may actually cause the fire to go out.
(see pelletheat.org for further information)

EPA COMPLIANCE

This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test methods
by Warnock Hersey , US. Pellet appliances that are designed with the combustion air supply exceeding 35:1 (by
ratio) are exempt from EPA regulations.

PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE.

+

+

8 1/4”

14 1/4”

3 3/4”

26”

23”

28”

8 3/4”

24”

31 1/2”

“V” Series V-130

“V” Series V-150

Exhaust

Air Inlet

+

+

7”

9 1/4”

12 ½”

5 ½”

3” Dia.

Exhaust

2”

Air Inlet

22”

Advertising
This manual is related to the following products:

CC2, CC1